This tip sheet covers some of the same tactical considerations of the previous tip sheets, but also covers scene preservation prior to arrival of fire marshals and what to do after the fire has been knocked down.

The FDNY has also produced a safety video to educate the public on how to charge, store and use lithium-ion batteries safely.

Recently, the FDNY issued Hazmat 20 – Lithium-Ion Mobility Device Fires. This tip will discuss operations for Lithium-ion (Li-Ion) batteries or mobility devices involved in fire. All members are encouraged to review the link/QR to the FD Books provided above for further review.

Lithium-ion batteries or mobility devices involved in fire:

  • Use a handline to extinguish the fire; flames from a Lithium-Ion Battery should be knocked down with copious amounts of water. Water application should continue until conditions are dormant-that is when no more flame, gas or smoke is being released from the battery or mobility device.
  • Li-Ion Batteries or mobility devices which are involved in fire, found within a fire area, or subjected to elevated temperatures MUST be moved from the area in which members will be operating. This should be accomplished before overhaul operations begin.
  • When a Li-Ion Battery or mobility device fire involves a 10-45 (any code) all members operating should be aware of the need for scene preservation prior to the arrival of the Fire Marshals.
  • When possible, prior to overhaul in the area of the lithium-ion battery or mobility device, members should conduct a diligent search for stray battery cells. These individual cells may have become dislodged from the battery pack during the fire or by the hose stream during extinguishment.

Recently, the FDNY issued Hazmat 20 – Lithium-Ion Mobility Device Fires. This tip will discuss operations for Lithium-ion (Li-Ion) batteries or mobility devices involved in fire after the fire has been knocked down. All members are encouraged to review the link/QR to the FD Books provided above for further review.

  • Firefighters must not place the Li-Ion battery pack or cells in the pocket of their bunker coat or pants.
  • When possible, members should move the Li-Ion batteries by use of a nonconductive tool, a shovel with a wooden handle or other method that doesn’t require members to carry in their hands.
  • he batteries or mobility device should be moved to the following location in order of preference until it can be appropriately over packed/mitigated by Hazmat Company 1 or a Hazmat Tech Unit:

When the battery or mobility device is in a location that makes removal via fire apartment window not practical, such as in an upper story apartment in a high-rise building, the Incident Commander may move the batteries or mobility device to a different location on the fire floor and ensure the batteries are protected by a charged hose line. The charged hose line will remain in place until overpacking/mitigation procedures have been completed by a Haz Tech Unit. A lithium-ion battery or mobility device shall NOT be moved in an elevator or via stairs unless overpacked (mitigated) by Hazmat Technicians and approved by the IC.

,

Related Resources

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex.

  • Digital Capabilities Resilience Guide & Toolkit

    Explore the IAFC Digital Capabilities Resilience Guide & Toolkit to help fire and EMS departments maintain essential operations during technology disruptions.

  • Executive Fire Officer Program (EFOP)

    Explore the Executive Fire Officer Program (EFOP) to advance fire service leadership through executive education, applied research and professional development.

  • What is US&R?

    Explore Urban Search & Rescue (US&R) task force capabilities, specialized teams, benefits and how fire departments can request resources during disasters.